LG Dryer Error Codes: What They Mean and How to Fix Them
LG dryer codes appear on the display, and many models also show Flow Sense bars for vent airflow. Codes and button names vary by model, so match what you see to your owner's manual. LG's usual reset is to unplug the dryer or trip its breaker, hold Start/Pause for five seconds while it is unpowered, then restore power and run a cycle. Fix the cause first, though: a reset will not clear a blocked vent.
LG Dryer Error Codes list
Exhaust vent restricted by about 75, 80, 90 or 95 percent
Common causes: Lint in the duct, a crushed or kinked vent hose, a jammed outside flap, long vent runs with many bends, or oversized loads
What you can try: Clean the lint filter, check the duct behind the dryer for kinks and make sure the outside flap opens fully. Dry smaller loads.
Call a technician if: The duct runs inside a wall or roof and needs professional cleaning, or the code persists after cleaning.
Possible lack of gas supply
Common causes: A closed gas valve or a gas supply problem, in addition to vent restriction
What you can try: Check the vent first. Confirm the gas valve behind the dryer is in the open position without loosening any fittings.
Call a technician if: The vent is clear. If you smell gas, leave the home and call your gas utility.
No current detected at the heater
Common causes: Usually home wiring: a tripped breaker, one half of a 240V breaker off, or a loose cord connection
What you can try: Turn the dryer's breaker off for at least 10 seconds and back on. Make sure the cord is fully plugged into its 240V outlet.
Call a technician if: The dryer still will not heat. Outlet voltage checks need a licensed electrician or technician.
Improper voltage in the power cord
Common causes: Possibly reversed wires at the terminal block on the back of the dryer
What you can try: Reset the breaker for at least 10 seconds. Leave the terminal block itself to a professional.
Call a technician if: The code returns. Cord wiring is not a DIY task.
Humidity (moisture) sensor error
Common causes: Residue from dryer sheets or softener on the sensor bars below the lint filter, or a failed sensor
What you can try: Wipe the sensor bars with a damp cloth and let them dry before the next cycle.
Call a technician if: HS returns. LG notes it can make the dryer run about 2.5 hours.
Door not fully closed
Common causes: Lint filter not seated, clothing in the door, or a door switch problem
What you can try: Seat the lint filter fully and close the door firmly. Unplug for five seconds, plug in, close the door and start a cycle.
Call a technician if: The code keeps coming back.
Thermistor (temperature sensor) problem
Common causes: A failed sensor or wiring fault
What you can try: Use LG's reset: unplug, hold Start/Pause for five seconds, restore power and run a cycle.
Call a technician if: The code returns after the reset.
Thermistor reading in cold conditions
Common causes: Cold outside air entering through an open or stuck vent flap, or steam cycles cooling the duct quickly
What you can try: Make sure the outside flap closes properly and is free of ice, snow or lint.
Call a technician if: tE2 continues after the flap is fixed.
Temperature out of range
Common causes: A sensor fault
What you can try: No homeowner fix. LG lists this as a service code.
Call a technician if: Every time it appears.
Gas dryer is not receiving gas
Common causes: A closed valve or kinked gas line
What you can try: Confirm the valve is open and the line is not kinked. If the dryer is new, contact the installer.
Call a technician if: The valve is open and the code remains.
Lint filter not inserted properly
Common causes: Filter pulled out or not seated
What you can try: Remove and reinsert the lint filter.
Call a technician if: The filter is seated and the message stays.
Power failure, usually after an outage
Common causes: An interruption in power during the cycle
What you can try: Unplug or trip the breaker, hold Start/Pause for five seconds, restore power and run a cycle.
Call a technician if: PF continues without outages.
Drain hose problem
Common causes: A kinked, crushed or clogged drain hose, an extended hose, or frozen sump water
What you can try: Straighten the drain hose and use LG's standard hose, then press Start/Pause.
Call a technician if: E13 returns.
How to clear the code
- Control reset (PF, tE1, tE3): unplug the dryer or trip its breaker, press and hold Start/Pause for five seconds, restore power and start a cycle.
- Door code (dE): unplug for five seconds, plug in, close the door firmly, choose a cycle and press Start.
- Power codes (nP, PS): turn the breaker off for at least 10 seconds.
- Not errors: CL is Child Lock (hold the Child Lock key for three seconds), and Check Filter is a reminder.
Flow Sense codes and dryer safety
LG built Flow Sense to warn you before a restricted vent becomes a bigger problem. A d90 or d95 code means very little air is leaving the dryer. Heat and lint build up inside, drying slows down, and the heating parts work harder than they should.
Do not keep running loads with a d90 or d95. Clean what you can reach, and if the duct goes through a wall, ceiling or roof, a professional vent cleaning is the safest route. If your dryer runs but stays cold, see our guide on an LG dryer not heating.
LG dryer repair in Metro Atlanta
Mr. Fixer repairs LG electric, gas and steam dryers across Metro Atlanta. Learn more on our dryer repair and LG appliance repair pages. Call (678) 866-3669 or book online.
Code still showing?
Our technicians repair LG dryers across Metro Atlanta, usually the same day. Diagnostic from $80, credited toward your repair.
Call (678) 866-3669FAQs
Does d80 mean my LG dryer is broken?
Usually not. On most models d80 means the exhaust vent is about 80 percent restricted, so the vent needs cleaning. On gas models it can also point to a gas supply issue.
Why does my LG dryer show nP and not heat?
LG says nP means no current is reaching the heater, which usually comes from home wiring, such as a tripped breaker or a loose 240V connection. Reset the breaker, and if it continues, have the outlet and dryer checked.
How do I clean the LG dryer humidity sensor?
The sensor is a pair of metal bars just below the lint filter opening. Wipe them with a damp cloth or paper towel and let them dry before running another load.
Codes and meanings vary by model and model year. Check your owner's manual for your exact model.
More error code guides
- LG Washer Error Codes
- Samsung Dryer Error Codes
- Whirlpool Dryer Error Codes
- LG Refrigerator Error Codes
- LG Dishwasher Error Codes
Troubleshooting guides

Dryer Not Heating? Causes, Safe Checks and Fixes
A dryer that runs but does not heat usually has a blown thermal fuse, a failed heating element (electric) or igniter (gas), a bad thermostat, or a tri…
Read the guide →
LG Dryer Not Heating: Causes and What to Check
An LG dryer that tumbles but stays cold usually has a blown thermal fuse, a failed heating element or igniter, a bad thermistor, or a tripped thermal …
Read the guide →
Dryer Takes Too Long to Dry? Causes and Fixes
A dryer that needs two or three cycles to finish a load is usually held back by restricted airflow: a clogged lint screen, a crushed or lint-packed ve…
Read the guide →